You are here
>
Product Range >> Process Measurement >> Temperature
Transmitters |
| |
|
| |
 |
|
TEMPERATURE TRANSMITTERS |
|
|
 |
|
|
|
|
|
Temperature Transmitters
are required to convert passive low level signal
from temperature sensors (resistance from RTDs, millivolts from thermocouples into active and
standard 4-20mA DC signals proportional to
temperature, for transmitting over long distance, or
for converting into an industry standard signal or
where there is a likelihood of signal distortion or
corruption by electromagnetic (EMI/EMC)
interferences.
|
|
Model - 782T
(Field Mounted Temperature Transmitter) |
|
|
|
|
|
|
 |
SPECIFICATIONS |
|
 |
 |
Type |
|
Fixed input, ranges (RTDs and
thermocouples) 2-wire transmitter |
 |
 |
Inputs |
|
Pt-100
RTDs, thermocouple J,K,R,S,T,E,B
(specify in order) |
 |
 |
Power |
|
12-38VDC,
2-wire loop powered |
 |
 |
Output |
|
4-20mA
DC, 600 ohms load @ 24VDC power |
 |
 |
Isolation |
|
Not
provided |
 |
 |
Enclosure |
|
Field-mounted IP-65, ABS or die-cast
aluminium |
 |
 |
Mounting |
|
Surface
mounted |
|
|
|
|
|
|
|
|
|
|
| |
|
Model - Dyna-TT
(DIN-rail/surface mounted Temperature
Transmitter) |
|
|
|
|
|
|
 |
SPECIFICATIONS |
|
 |
 |
Type |
|
Fixed input, ranges (RTDs and
thermocouples) 2-wire transmitter |
 |
 |
Inputs |
|
Pt-100
RTDs, thermocouple J,K,R,S,T,E,B
(specify in order) |
 |
 |
Power |
|
10-30VDC, 2-wire loop powered |
 |
 |
Output |
|
4-20 mA
DC, 600 ohms load @ 24VDC power |
 |
 |
Isolation |
|
1000VDC,
3-port isolation (I/P-O/P/P/S) |
 |
 |
Enclosure |
|
Field-mounted IP-65, ABS or die-cast
aluminium |
 |
 |
Mounting |
|
In RTD /
thermocouple sensor head (supplied
separate or with sensor) |
|
|
|
|
|
|
|
 |
|
|
|
| |
| |
|
Model - 782F
(Field Mounted Temperature Transmitter) |
|
|
| |
|
|
|
|
 |
SPECIFICATIONS |
|
 |
 |
Type |
|
Fixed input, ranges (RTDs and
thermocouples) |
 |
 |
Inputs |
|
Pt-100
RTDs, thermocouple J,K,R,S,T,E,B
(specify in order) |
 |
 |
Power |
|
12-38VDC,
2-wire loop powered |
 |
 |
Output |
|
4-20mA DC
, 600 ohms load @ 24VDC power |
 |
 |
Isolation |
|
1000VDC,
3-port isolation (I/P-O/P/P/S) |
 |
 |
Enclosure |
|
Field-mounted IP-65, ABS or die-cast
aluminium |
 |
 |
Mounting |
|
Surface
mounted |
|
|
|
|
|
|
|
| |
| |
|
Model - Dyna-IS
(Field Mounted Temperature Transmitter) |
|
|
| |
|
|
|
|
 |
SPECIFICATIONS |
|
 |
 |
Type |
|
Fixed input, ranges (RTDs and
thermocouples) |
 |
 |
Inputs |
|
Pt-100
RTDs, thermocouple J,K,R,S,T,E,B
(specify in order with range) |
 |
 |
Power |
|
12-38VDC,
2-wire loop powered |
 |
 |
Output |
|
4-20mA DC
, 600 ohms load @ 24VDC power |
 |
 |
Display |
|
3 ½
digits, LCD display for temperature |
 |
 |
Enclosure |
|
IP-65, aluminium alloy, ex-areas |
 |
 |
Mounting |
|
Field-mounted 2” pipe mounting
bracket provided |
|
|
|
|
|
|
|
| |
|
| |
|
|
|
 |
SPECIFICATIONS |
|
 |
 |
Type |
|
Microprocessor-based, programmable
(RTDs and thermocouples) |
 |
 |
Inputs |
|
Pt-100
RTDs, thermocouple J,K,R,S,T,E,B |
 |
 |
Power |
|
100-264VAC, 24VDC powered versions |
 |
 |
Output |
|
4-20mA DC
x 600 ohms load |
 |
 |
Isolation |
|
1000VDC,
3-port isolation (I/P-O/P/P/S) |
 |
 |
Ranges |
|
Programmable as per sensor limits |
 |
 |
Mounting |
|
35mm
DIN-rail mounted |
|
|
|
|
|
|
|
|
| |
| |
|
Model -
Dyna-AIO
(All-in-one Temp. Transmitter-cum-Signal
Repeater) |
|
|
| |
|
|
|
|
 |
SPECIFICATIONS |
|
 |
 |
Type |
|
Microprocessor-based, programmable
(RTDs, thermocouples, mA, VDC) |
 |
 |
Inputs |
|
Pt-100
RTDs, thermocouple J,K,R,S,T,E,B,
4-20 mADC |
 |
 |
Power |
|
100-264VAC, 24VDC powered versions |
 |
 |
Output |
|
4-20mA DC
x 600 ohms load (maximum 4 outputs) |
 |
 |
Isolation |
|
1000VDC
3-port isolation (I/P-O/P/P/S) |
 |
 |
Ranges |
|
Programmable as per sensor limits |
 |
 |
Mounting |
|
35mm